Описание

Function Emergency stop module
Also suited as safety gate monitor +
Cat. / PL according to EN ISO 13849-1 4/e
SIL CL according to IEC/EN 62061 3
1- / 2-channel 1, 2
Output contacts max. 3 s, 1 o
Thermal current Ith max. 10 A
Nominal voltage DC +
Nominal voltage AC +
Connection PS
Width 100 mm
Type BN 5983
According to- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061- Safety Integrity Level (SIL) 3 to IEC/EN 61508 Output: 3 NO, 1 NC contacts for AC 400 V Optionally gold-plated contacts to switch small loads (input for PLC) 1-channel or 2-channel connection LED displays for channels 1 and 2 Feedback circuit X3 - X4 for monitoring external contactors Removable terminal strips Overvoltage and short circuit protection Width 100 mm''